摘要:目的 分析微生物检验中微滤膜分离方法的样本污染及检出结果。方法 将本疾病预防控制中心于 2023 年 3 月至 2024 年 3 月采集的 122 份微生物待检样本纳入研究,同时进行平板培养法与微滤膜分离技术检验,对比组间检验结果及对样本污染情况的影响。结果 平板培养法与微滤膜分离技术分别从 122 份微生物待检样本中检出 67 份、64 份阳性样本,二者初检阳性率、复检阳性率与漏检率对比,差异无统计学意义(P>0.05);但 微滤膜分离技术检验微生物的报告时间短于平板培养法,样本污染率低于平板培养法,阳性菌回收率则显著高于平板培养法,差异有统计学意义(P<0.05)。结论 微滤膜分离技术检验微生物的准确性与平板培养法基本一致,并且可明显缩短报告时间,减少样本污染,提高阳性菌回收率,整体优势更加突出。
Abstract: Objective To analyze the sample contamination and detection results of the microfiltration membrane separation method in microbiological testing. Methods A total of 122 microbial samples to be tested collected by the Center for Disease Control and Prevention from March 2023 to March 2024 were included in the study. Meanwhile, plate culture method and microfiltration membrane separation technology tests were conducted. The test results between groups and the impact on sample contamination were compared. Results The plate culture method and microfiltration membrane separation technology detected 67 and 64 positive samples from 122 microbial samples to be tested, respectively. There was no statistically significant difference in the initial positive rate, re-positive rate and missed detection rate between the two (P>0.05). However, the reporting time for microbial testing by microfiltration membrane separation technology was shorter than that of the plate culture method, the sample contamination rate was lower than that of the plate culture method, and the recovery rate of positive bacteria was significantly higher than that of the plate culture method. The difference was statistically significant (P<0.05). Conclusion The accuracy of microfiltration membrane separation technology in testing microorganisms is basically the same as that of the plate culture method. Moreover, it can significantly shorten the reporting time, reduce sample contamination, and increase the recovery rate of positive bacteria. The overall advantages are more prominent.
引用本文
按标准格式复制,或导出到文献管理软件参考文献
共 0 条| 文章编号 | 2025-05-052(期号内编号) |
|---|---|
| 栏目 | 检验与方法 |
| 作者 | 董爱凤;李振伟 |
| 作者单位 | 济南市莱芜区疾病预防控制中心 |
| 卷期页码 | 2025, (05) |
| 发布时间 | - |
| 出版时间 | - |
| 引用信息 | [1]董爱凤,李振伟.微生物检验中微滤膜分离方法的样本污染及检出结果分析[J],2025,01(05):. |
| 全文地址 | 在知网查看该文(kns.cnki.net) |
| 数据抓取时间 | 2026-09-22T12:43:08 |