食管肿瘤在强调放射治疗中靶区位移的研究及其对放射剂量学的影响

江油市九〇三医院 2.中江县人民医院

10下载次数 0被引频次 17阅读次数 15参考文献
知网阅读全文
摘要

目的 研究食管癌调强放疗(IMRT)肿瘤靶区移位以及对放疗剂量学的影响。方法 分析2024年11月至2025年8月我院收治的60例食管癌放疗患者的临床资料,将所有患者按照接受容积调强放疗(VMAT)或接受适形调强放疗(IMRT)分为两组,两组患者均在放疗后测量靶区几何中心在X、Y、Z轴上的移位度,并进行三维适形和调强放疗中在靶区相同移位情况下肿瘤靶区、危及器官的剂量变化的对比。结果 在相同移位下,靶区移位后与靶区移位前的差值比较,与VMAT的大体肿瘤靶区(GTV D95%)、临床靶区(CTV D95%)及计划靶区(PTV D95%)差值相比,IMRT的剂量变化差值更高,且组间差值均有统计学差异(P<0.05);IMRT与VMAT计划下,靶区移位后危及器官(OARs)剂量与初始计划之间依然存在偏差,而IMRT在左肺(V20)、右肺(V20)、心脏(V30)方面前后的偏差更大,差异均有统计学意义(P<0.05)。结论 食管癌VMAT和IMRT治疗过程中由于靶区移位,均会导致患者肿瘤靶区(GTV、CTV、PTV)和OARs剂量变化,而IMRT技术剂量偏差更大,因此更应制定标准化质量控制,才能提高放疗效果,减少不良反应。

Abstract

Objective To study the displacement of tumor target areas in intensity-modulated radiotherapy(IMRT) for esophageal cancer and its impact on radiotherapy dosimetry. Methods The clinical data of 60 patients with esophageal cancer who received radiotherapy in our hospital from November 2024 to August 2025 were analyzed. All patients were divided into two groups according to whether they received volumetric intensity-modulated radiotherapy(VMAT) or conformal intensity-modulated radiotherapy(IMRT). Both groups measured the displacement of the target volume's geometric center along the X, Y, and Z axes following radiotherapy. They then compared dose changes to the tumor target volume and organs at risk under identical displacement conditions during three-dimensional conformal radiotherapy and intensitymodulated radiotherapy. Results Under the same displacement, when comparing the differences between the target area after displacement and before displacement, compared with the differences of the gross tumor target area(GTV D95%), clinical target area(CTV D95%), and planned target area(PTV D95%) of VMAT, the dose change difference of IMRT was higher, and the differences between groups showed statistically significant differences(P<0.05). Under the IMRT and VMAT plans, there was still a deviation between the dose of organs at risk(OARs) after target displacement and the initial plan. Moreover, the deviations before and after IMRT in the left lung(V20), right lung(V20), and heart(V30) were even greater, and the differences were statistically significant(P<0.05). Conclusion During the treatment of esophageal cancer with VMAT and IMRT, due to the displacement of the target area, it will lead to changes in the tumor target area(GTV, CTV, PTV) and OARs dose of the patient. The deviation of IMRT technology is even greater. Therefore, it is even more necessary to formulate standardized quality control to improve the radiotherapy effect and reduce adverse reactions.

引用本文

按标准格式复制,或导出到文献管理软件
[1]刘静雯,苏秀琳.食管肿瘤在强调放射治疗中靶区位移的研究及其对放射剂量学的影响[J].疾病预防与控制,2026,2(02):145-148.